cordon chauffant GELTRACEFROST PROTECTING TAPE IS A RELIABLE AND ECONOMICAL SOLUTION TO YOUR PROBLEMS OF FROST PROTECTION

Thanks to the thermostat and the self limiting heating cable

Applications:
GELTRACE™ range is used for the frost protection of pipes. In the protigel™+ version, the thermostat automatically switches on the tape when the temperature falls under +5°C. It enables substantial energy savings and offers in complement the advantages and the safety of a self-regulating tape.
Avoids drainings and permanent use of hydraulic networks. Easy to implement. Available on stock.
Adjustable length according to the network size. Tape finished and controlled in the factory.
No overheating risk thanks to its self regulating system.
When it is cold, the polymer shrinks and facilitates the flow of current, thereby increasing the temperature of the cable. As it gets warmer, the polymer expands and prevents the current: the Self Regulating cable heats less than before.
Finally, a « parallel » technology allows the cable to be cut to desired length directly on the site. Exact fit the length of heating cable for your needs.

Description of GELTRACE self limiting heating cable

  1. Bus wire Cu nickel-plated (2×0.55mm²)
  2. Self limiting heating element
  3. Insulation
  4. Tin-plated copper protective earth wires with Protective aluminium foil
  5. Thermoplastique (TPE-O) outer jacket (Black)
  6. Thermostat 5°C
  7. Cold lead (1m 3x1.5mm²)

 

Reference    Designation     Power
GELTRACE-1 Self Limiting cable, 1m lenght, with 5°C thermostat and 1m cold lead   15 W at 10°C
GELTRACE-xx Self Limiting cable, 1m to 35m lenght, with 5°C thermostat, 1m cold lead (available from 1 to 35m) 15 W/m at 10°C
GELTRACE-35 Self Limiting cable, 35m lenght, with 5°C thermostat, 1m cold lead  450 W at 10°C

 


GELTRACE Heating Cable Description

  • Nominal Voltage: 230V
  • Maximum length circuit: GELTRACE-35…………. 35 m
  • Tolérances sur la puissance: -0/+5W
  • Maximum exposure temperature (energised): 65°C         
  • Maximum exposure temperature (deenergised): 80°C        
  • Temperature Class: T6               
  • Minimum Bending Radius: 27 mm
  • Minimum installation temperature: -35°C                
  • Weight approx.: 66 kg/km

Qualifications Produits CE

GELTRACE™ PACK Fabrication du cordon électrique chauffant GELTRACECOMPOSITION

A Self Regulating Tape, An integrated thermostat limiting the temperature, a cable of connection two phases + ground.

SELF LIMITING HEATING CABLE ADVANTAGES

GELTRACE™ as a Self Regulating tape it can be superimposed without any risk of destruction.
GELTRACE™ can be cut in order to be adapted to the pipe length. A termination kit including a heat-retractable cap is provided for this purpose.
The lagging thickness of insulator (rockwool or synthetic insulator) can rank above 13 mm. The Self Regulating Tapes avoids every overheating risk.
The combination of a thermostat and a self-regulation enables important energy savings in comparison with other tracing systems.

CAUTION

The Tapes must be used along the under generator of piping.
Do not install GELTRACE™ on pipes whose temperature can reach 65°C.

INSULATION

Measure the length of piping.
Choose the closest length of tape.
Thanks to the self-regulation system of GELTRACE™, it is possible to cut the cable to the desired length. You just have to fix the cap provided at the end of the cable

INSTALLATION

Pipe must be clean and dry.
Fix the GELTRACE™ cable on piping using a PVC or aluminium adhesive tape. We advise the use of the standard aluminium adhesive tape ELAA-50. It enables a better distribution of heat in plastic pipes.
Install the heat insulation. Thickness recommended is 13 mm of polyurethane foam.

CONNECTION

The connecting cable is composed of 3 wires (2 live wires + ground).
Check your installation is correctly grounded to ensure a maximum protection.

POSITION OF THE THERMOSTAT

The thermostat (black shrink sleeve marking ELTRACE) will be placed and fixed on by the provided collars. It will be covered with insulation in order to control the pipe temperature and to save the maximum energy.
The thermostat will take care of the powering when the temperature of piping is lower than +5°C, and will cut off the supply if it goes over +9°C.

Product conforms to the Directive EMC 89/336/E6 EN 55014.93



Download GELTRACE heat cable Datasheet

Contact us now !

  • Technical information on frost protection for pipes? Our engineers specializing in electric heating cables are at your service.
  • A price request for underfloor heating, electric heated floors or any other question...? Our sales department is at your disposal.
    Maintaining the temperature of industrial processes? We are listening to you
  • Contact us now at +33 1.64.62.04.40, all our technical, commercial and logistics teams are dedicated to you.Un renseignement technique sur de la mise hors gel de tuyauteries ? Nos ingénieurs spécialiste en câbles chauffants électriques sont à votre écoute.

Contact us now

Plan du site - Sitemap

Informations importantes | Politique de traitement des données personnelles | Conditions Générales de Vente - CGV